Keep useful
warmth inside
A counterflow heat exchanger transfers warmth from extracted air to the incoming supply, reducing ventilation heat loss.
Fresh Air | Heat Recovery | Smart Control
Bring fresh air into living spaces while recovering useful warmth from the air leaving your home.
The Reneo S 400 combines up to 123.6 l/s airflow, an insulated casing and connected control in an upright unit. This version is supplied without an integrated preheater.

Continuous fresh-air supply, moisture extraction and heat recovery work together to make everyday ventilation part of a comfortable home.
A counterflow heat exchanger transfers warmth from extracted air to the incoming supply, reducing ventilation heat loss.
Filtered air reaches living rooms and bedrooms while stale, moisture-laden air is extracted from kitchens, bathrooms and utility rooms.
The bypass avoids reheating cooler incoming air when conditions allow. It supports summer ventilation; it does not provide active cooling.
Efficient EC motors provide adjustable fan operation, helping the commissioned system deliver the airflow required by the ventilation design.
Blauberg Home puts everyday ventilation settings within reach on your smartphone. Set a weekly schedule, use boost when needed and keep track of filter reminders.
S21 and S71 control versions support the app. Wall panels are optional; confirm compatibility with the selected control version.
Explore the optional S25 LCD wall controller →


Suited to homes and self-builds needing more airflow than the Reneo 270 can provide at the design duty, with space for an upright unit and coordinated 160 mm duct routes.
Coordinate plant space, duct routes, drainage and access early. Wall or floor mounting gives architects, consultants and installers flexibility in the layout.
Fresh air in living spaces, moisture extraction from wet rooms and straightforward controls for everyday use.
Check the unit dimensions alongside duct connections, drainage and maintenance access.

Unit weight: 26 kg. Keep the cover, filters and heat exchanger accessible. Allow for ductwork and condensate drainage; floor supports must provide at least 150 mm for drainage. Unit dimensions are not installation clearances.
View the installation guidance →Compare the key figures, then select against the project airflow and system resistance. Maximum airflow is not the available airflow at every pressure.
| Specification | Reneo S 400 |
|---|---|
| Maximum airflow | 123.6 l/s |
| Heat recovery efficiency | Up to 93% |
| Summer bypass | Yes |
| Supply filter | G4 standard; F7 optional |
| Extract filter | G4 |
| Integrated preheater | No |
| Preheater power | Not fitted |
| Maximum total power | 178 W |
| Maximum total current | 1.4 A |
| SEC class | A+ |
| Duct connections | 160 mm diameter |
| Mounting / arrangement | Wall or floor / left-hand |
| Electrical supply | 230 V, 50/60 Hz |
| Maximum fan power | 178 W |
| Casing / insulation | EPP / 45 mm |
| Heat exchanger | Counterflow polystyrene |
| Unit weight | 26 kg |
Both figures are at 70% airflow. Sound pressure is stated in spherical free-field conditions. Installed room noise depends on duty, location and attenuation.
Use the model manual for installation requirements and ask our technical team for the applicable performance data for your chosen configuration.
Download Reneo User GuideShare your plans and ventilation requirements. Our team can help you select the unit and coordinate the next steps.
| EAN Number | 5056194044790 |
|---|---|
| Impeller Type | Centrifugal |
| Maximum Airflow Rate (l/s) | 55 |
| Maximum Airflow Rate (m3/h) | 200 |