Efficient motor, adjustable speed
An electronically commutated motor drives the backward-curved centrifugal impeller. Rated for continuous operation, with automatic restart after thermal protection trips.
Commercial & Residential | Supply & Extract | 1-phase EC
Six sizes for ducted ventilation. EC control across the range.
CENTRO EC inline centrifugal fans provide supply or extract ventilation for commercial and residential buildings. Each combines a high-efficiency EC motor with a backward-curved impeller and an impact-resistant ABS casing. Six models cover 100–315 mm circular ductwork, with maximum airflow up to 1,500 m³/h (417 l/s).
Use an external 0–10 V controller to set the fan speed, or connect a compatible building management system for automatic adjustment. Mounting brackets are included; the controller and ductwork are supplied separately.

An electronically commutated motor drives the backward-curved centrifugal impeller. Rated for continuous operation, with automatic restart after thermal protection trips.
Accepts a speed signal from an external EC controller, sensor controller or building management system. Controls are supplied separately.
The moulded ABS housing has circular duct connections and an external terminal box. Unit protection is IPX4; motor protection is IP44.
Two mounting brackets support floor, wall or ceiling fixing. The fan can be installed horizontally or vertically, following the user guide.

CENTRO EC provides ducted supply or extract ventilation for offices, shops, communal washrooms and homes. Its backward-curved centrifugal impeller moves air against the resistance of ducts, bends and grilles. Published airflow, sound and dimensional data support fan selection.
View CENTRO EC technical dataFloor, wall or ceiling mounting gives you more choice over the fan position. Two brackets are supplied, and the casing can be mounted horizontally or vertically. The external terminal box and removable cover provide access for wiring and cleaning. Overall dimensions for each model are listed below.
View CENTRO EC technical data

The standard range covers 100, 125, 150, 200, 250 and 315 mm duct connections. CENTRO EC 150 also accepts 160 mm ductwork, giving stockists one product reference for both sizes. Every fan comes with two mounting brackets, fixing screws and dowels, and the user guide. Controllers, sensors and ductwork are separate items.
View CENTRO EC technical data
Ventilation demand can change as rooms fill up or empty. With a compatible external controller, CENTRO EC can increase or reduce fan speed in response. A sensor controller can respond to conditions such as CO₂ or humidity; a BMS can set speed to a building schedule. Those controls are separate from the fan.
Talk to us about your projectA separate EC speed controller sets the fan speed through its 0–10 V input. For automatic adjustment, a compatible sensor controller or building management system (BMS) can supply that signal instead. For example, an external CO₂ or humidity controller can vary speed as conditions change. The standard fan has no built-in room sensor or user speed control.
The EC motor has thermal protection with automatic restart. Isolate the electrical supply before opening or cleaning the fan. Inspect and clean it at least every six months, following the user guide.

| Specification | CENTRO EC 100 | CENTRO EC 125 | CENTRO EC 150 | CENTRO EC 200 | CENTRO EC 250 | CENTRO EC 315 |
|---|---|---|---|---|---|---|
| Duct connection | 100 mm | 125 mm | 150 / 160 mm | 200 mm | 250 mm | 315 mm |
| Maximum airflow | 340 m³/h (94 l/s) | 420 m³/h (117 l/s) | 630 m³/h (175 l/s) | 885 m³/h (246 l/s) | 1,250 m³/h (347 l/s) | 1,500 m³/h (417 l/s) |
| Rated power [W] | 82 | 84 | 82 | 84 | 165 | 165 |
| Current [A] | 0.62 | 0.64 | 0.63 | 0.64 | 1.1 | 1.15 |
| Speed [rpm] | 3400 | 3600 | 3400 | 2700 | 2600 | 2500 |
| Sound pressure at 3 m [dBA] | 40 | 42 | 45 | 47 | 48 | 48 |
| Electrical supply / frequency | 1-phase / 50/60 Hz | 1-phase / 50/60 Hz | 1-phase / 50/60 Hz | 1-phase / 50/60 Hz | 1-phase / 50/60 Hz | 1-phase / 50/60 Hz |
| Speed control signal | 0–10 V | 0–10 V | 0–10 V | 0–10 V | 0–10 V | 0–10 V |
| Transported air temperature | −25 to +60 °C | −25 to +60 °C | −25 to +60 °C | −25 to +60 °C | −25 to +60 °C | −25 to +60 °C |
| Ambient operating temperature | +1 to +40 °C | +1 to +40 °C | +1 to +40 °C | +1 to +40 °C | +1 to +40 °C | +1 to +40 °C |
| Unit / motor protection | IPX4 / IP44 | IPX4 / IP44 | IPX4 / IP44 | IPX4 / IP44 | IPX4 / IP44 | IPX4 / IP44 |
| Weight [kg] | 2.0 | 2.2 | 2.5 | 3.0 | 4.3 | 4.9 |
Maximum airflow is the catalogue maximum, not the airflow at every installed duty. Select from the fan curve at the required airflow and system resistance. Sound figures are sound pressure levels at 3 m; room noise depends on the duty and installation.

| Model | D | D1 | B | L | L1 | L2 | L3 | Weight [kg] |
|---|---|---|---|---|---|---|---|---|
| CENTRO EC 100 | 100 | 250 | 270 | 230 | 30 | 27 | 30 | 2.0 |
| CENTRO EC 125 | 125 | 250 | 270 | 220 | 30 | 27 | 30 | 2.2 |
| CENTRO EC 150 | 150 / 160 | 300 | 310 | 286 | 30 | 30 | 30 | 2.5 |
| CENTRO EC 200 | 200 | 340 | 354 | 276 | 30 | 30 | 40 | 3.0 |
| CENTRO EC 250 | 250 | 340 | 354 | 265 | 30 | 30 | 40 | 4.3 |
| CENTRO EC 315 | 315 | 400 | 414 | 276 | 40 | 55 | 40 | 4.9 |
D, D1, B, L, L1, L2 and L3 correspond to the manufacturer drawing. Dimensions are in mm. Weight is in kg. Allow additional room for connections and maintenance.
For help choosing the fan or a compatible controller, send Blauberg UK the duct size, required airflow and system pressure. CENTRO EC is for general clean-air ventilation; specialist process extract, commercial kitchen grease extract and smoke control require a different fan selection.
| Impeller Type | Centrifugal |
|---|---|
| Motor Type | EC |
| Electrical Supply | 1 Phase 220/250 50/60Hz |